美国GRACO隔膜泵4D350系列
美国GRACO精加工高压隔膜泵Endura-Flo 4D350 High Pressure Diaphragm Pumps.350 cc per cycle and 400 psi (28 bar) maximum fluid pressure in a compact pump.
- 上一个:4D150固瑞克高压隔膜泵
- 下一个:美国GRACO精加工低压隔膜泵
美国GRACO隔膜泵4D350系列
美国GRACO精加工高压隔膜泵Endura-Flo 4D350
High Pressure Diaphragm Pumps
350 cc per cycle and 400 psi (28 bar) maximum fluid pressure in a compact pump
The Endura-Flo 4D350 ensures long-lasting durability and can withstand runaway conditions better than other diaphragm pumps. This easy-to-install pump offers low pulsation output and smooth changeover for quick color changes, saving you time and money.
功能:350 cc per cycle
Highest pressure ratio in the industry at 4:1
Redesigned diaphragm lasts longer and can hold up to extreme operating conditions better
Easy access to critical components provides fast online maintenance
Superior durability for abrasive materials
Innovative design ensures easy access to critical components for fast, online repair
Minimal solvent to flush and consistent startup pressure make it perfect for multiple color change and piggable systems
DataTrak option prevents runaway and tracks material usage
Pumps are easily configurable for custom installations
美国GRACO隔膜泵4D350系列规格:
Endura-Flo 4D150 Diaphragm Pump | |
Maximum air input pressure | 7 bar, 0.7 MPa |
Maximum fluid working pressure | 28 bar, 2.8 MPa |
Maximum static fluid pressure | 30 bar, 3.0 MPa |
Ratio | 4:1 |
Maximum recommended continuous cycle rate | 20 cycles per minute |
Volume per cycle (double stroke) | 150 cc per cycle |
Ambient and operating temperature range. Use dry compressed air when operating at low temperatures. | 0 to 50°C |
Dry suction lift | 7.0 m |
Wet suction lift | 8.8 m |
Air inlet size | 1/4 npt |
Fluid inlet size | 1 in. Tri-Clamp Flange, 1/2 in npt, or 1/2 in bspp |
Fluid outlet size | 1 in. Tri-Clamp Flange, 1/2 in npt, or 1/2 in. bspp |
Weight (approximate) | 14 kg |
Wetted parts | stainless steel, perfluoroelastomer (FFKM), PTFE, Polyphenylene Sulfide (PPS) |
Average Sound Pressure Levels in dBA at 20 cpm [measured at 1 meter (3.28 ft) horizontal, 1.5 meter (4.9 ft) above the equipment] | |
At 70 psi (0.5 MPa, 5.0 bar) | 62.3 dBA |
At 100 psi (0.7 MPa, 7.0 bar) | 62.9 dBA |
Sound Power measured per ISO 9614–2. | |
At 70 psi (0.5 MPa, 5.0 bar) | 70.8 dBA |